| Model | Type | Hazardous Area Ex Approvals | Functional Approvals | ||
| US | ATEX (EU) | Other | |||
| 200 Series | Open Path IR (Flash) | UL File No. E209870(4) |
ATEX1161(1) ATEX1165(2) | GOST R | - |
| 400 Series | Open Path UV | ||||
| 300 Series | Open Path IR (Lamp) | UL
|
FM Project ID 3032358(6) |
||
| XENON 700 Series | Open Path IR (Flash) | - | ATEX1406X(3) | - | |
Notes:
(1) EX II 2G SIRA00ATEX 1161 - EExd IIB + H2 T6 Amb. Temp. = -40°C to +55°C
(2) EX II 2G SIRA00ATEX 1165 - EExde IIB + H2 T6 Amb. Temp. = -40°C to +55°C
(3) EX II 2(1) GD SIRA03ATEX 1406X - EEx d e [ia] IIC T5 Amb. Temp. = -40°C to
+55°C
(4) UL Approval for Enclosures for Use in Hazardous Locations Class I, Group C
and D.
(5) FM Approved for use in hazardous locations Class I Division I, Groups E, F
and G Class II Division I, Groups E, F and G
(6) Performance requirement for open path gas monitors, Class No. 6325
Spectrex's SafEye 227 IR (Infrared) Open Path and SafEye 420 UV (Ultraviolet) Open Path Gas Detectors have been verified under the EPA's Environmental Technology Verification ProgramŽ.