Approvals - SharpEye Optical Flame Detectors

NEW 40/40 Series Flame Detectors


Model Type Hazardous Area Ex Approvals Functional Approvals SIL-2 Other Approvals
US ATEX (EU) Other FM EN54-10
40/40U UV                   FM Project ID 3029553 (17) 07 ATEX 1250(19) IECEx
SIR 07.0085(20)

 

CSA Project ID 3029553 (17)

Project ID 3029553 (17) TE-243256a 968/EZ326.00/08  
40/4UB UV with BIT
40/40L UV/IR
40/40LB UV/IR with BIT
40/40L4 UV/IR
40/40L4B UV/IR with BIT
40/40I IR3 DNV A-11020
40/40M Multi IR  

 

20/20 Series Flame Detectors

 

Model Type Hazardous Area Ex Approvals Functional Approvals SIL-2 Other Approvals
US ATEX (EU) Other FM EN54-10
20/20U UV   FM Class 3260 Project ID 3013474(1)

 

ATEX1160(2)

ATEX1162(3)

CSA LR 102007-2(1)

 

GOST R

Project ID 3013474(17)

 

Project ID 3020071(17)

-

 

- -
20/20UB UV with BIT(A)
20/20L UV/IR ABS
(Proj No. 1627964)
20/20LB UV/IR with BIT(A)
20/20F Fast UV/IR - ATEX1161(4)

ATEX1165(5)

- - - - -
20/20I IR3 FM Class 3260 Project ID 3013474(1) ATEX1163(6) ATEX1164(7) CSA LR

102007-2(1)

GOST R

Project ID 3013474(17)

 

Project ID 3020071(17)

- - Calif State Fire Marshal(18)
20/20SI IR3 GOST R G207121   DNV A-10899

ABS
(Proj No. 1627964)

Calif State Fire Marshal(18)

20/20SIS IR3 - - - TUV No. 968/EZ 305.00/08 -
20/20SH Hydrogen FM Class 3260 Project ID 3020071(1) Project ID 3020071(17) - - Calif State Fire Marshal(18)
20/20SHS Hydrogen - - - - TUV No. 968/EZ 305.00/08 -
20/20FI Fast IR3 - - - -   -
20/20R Single IR - GOST R - - -
20/20CTIN & CTIP CCTV UL
File No. E209870(16)
ATEX1163(10) ATEX1164(11) Project ID 3020071(17) - -
20/20XI XI Elite IR3   ATEX1407X(8) - G206033 -

 

 

20/20 Mini Flame Detectors

 

Model Type Hazardous Area Ex Approvals Functional Approvals SIL-2 Other Approvals
US ATEX (EU) Other FM EN54-10
20/20MI-3 Mini IR3                - ATEX 2010(9) GOST R Project ID 3013906(17) - - -
20/20MI-1 Project ID 3020071(17) G207073 DNV A-10899

ABS
(Proj No. 1627964)
20/20MR Mini Single IR - -
20/20MH Mini Hydrogen
20/20MU Mini UV    
20/20ML Mini UV/IR    

 

Accessories

 

Model Type Hazardous Area Ex Approvals Functional Approvals SIL-2 Other Approvals
US ATEX (EU) Other FM EN54-10
20/20-310 IR3 Fire Simulator - ATEX 225(12)  GOST R - - - -
20/20-311 UV/IR Fire Simulator
20/20-312 Single IR Fire Simulator
20/20-313 Hydrogen Fire Simulator


(A) - Built-in-Test (BIT)

Notes:

(1) Class I, Div 1, Groups B, C & D, Class II, Div. 1, Groups E, F & G, NEMA 250 6P
(2) EX II 2G SIRA00ATEX 1160 - EExde IIB + H2 T5 Amb. Temp. = -40°C to +70°C
(3) EX II 2G SIRA00ATEX 1162 - EExd IIB + H2 T5 Amb. Temp. = -40°C to +70°C or T4 Amb.
                                                                                Temp. = -40°C to +85°C
(4) EX II 2G SIRA00ATEX 1161 - EExd IIB + H2 T5 Amb. Temp. = -40°C to +70°C
(5) EX II 2G SIRA00ATEX 1165 - EExde IIB + H2 T5 Amb. Temp. = -40°C to +70°C
(6) EX II 2G SIRA00ATEX 1163 - EExd IIB + H2 T5 Amb. Temp. = -40°C to +70°C or T5 Amb.
                                                                                Temp = -40°C to +85°C
(7) EX II 2G SIRA00ATEX 1164 - EExde IIB + H2 T5 Amb. Temp. = -40°C to +70°C
(8) EX II 2(1) GD SIRA03ATEX 1407X - EEx d e [ia] IIC T5 Amb. Temp. = -40°C to +70°C
(9) EX II 1 GD T123C SIRA04ATEX 2010 - EEx ia IIC T5 Amb. Temp = -40°C to +60°C or T4 Amb.
                                                                                        Temp. = -40°C to +85°C
(10) EX II 2G SIRA00ATEX 1163 - EExd IIB + H2 T5 Amb. Temp. = -20°C to +55°C
(11) EX II 2G SIRA00ATEX 1164 - EExde IIB + H2 T5 Amb. Temp. = -20°C to +55°C
(12) EX II 2G NEMKO 02ATEX225 - EExd IIB T5 Amb. Temp. = -20°C to +50°C
(13) EX II 2G SIRA00ATEX 1161 - EExd IIB + H2 T6 Amb. Temp. = -40°C to +55°C
(14) EX II 2G SIRA00ATEX 1165 - EExde IIB + H2 T6 Amb. Temp. = -40°C to +55°C
(15) EX II 2(1) GD SIRA03ATEX 1406X - EEx d e [ia] IIC T5 Amb. Temp. = -40°C to +55°C
(16) UL Approval for Enclosures for Use in Hazardous Locations Class I, Group C and D.
(17) FM Approval for Industrial Applications per Class 3260, NEMA 250 6P
(18) California State Fire Marshal - Building Materials Listing Program
(19) EX II 2GD SIRA07ATEX1250 - Ex de IIB+H2 T5 Ta -55°C to +75°C, Ex tD A21 IP66/X7 T95°C or Ex
       de IIB + H2 T4 Ta -55°C to +85°C, Ex tD A21 IP66/X7 T105°C
(20) IEXEx SIR 07.0085 - Ex de IIB+H2 T5 Ta -55°C to +75°C, Ex tD A21 IP66/X7 T95°C or Ex de IIB +
       H2 T4 Ta -55°C to +85°C, Ex tD A21 IP66/X7 T105°C